CE Bipolar Coblation Wand Simultaneous Coagulation and Suction Electrode
Product Advanatages
(a) Soft Palate Coblation Wand DZX-E3230-A130 is a three-stage probe that features front and back poles. The first and second poles are used for punching, while the first, second, and third poles are used for ablation and stopping bleeding. This multi-functional design allows for a variety of procedures to be performed with a single device.
(b) It also includes a blade for perforation, ablation, coagulation, and hemostasis. This blade can be used to cut tissue when necessary, providing an additional level of versatility.
(c) It is designed with ergonomic principles in mind, ensuring comfortable and efficient use during medical procedures. This design minimizes the risk of hand fatigue and discomfort for the medical professional.
(d) It is primarily used for soft palate uvula, tonsil perforation ablation, and UPPP surgery. These procedures require a high level of precision and accuracy, which can be achieved with the multi-functional design of this medical device.
Specification
Model |
DZX-E3230-A130 |
Length |
130mm |
Diameter |
3.2mm |
Angle |
30° |
Working Degree |
40-70 degree |
Applications
epistaxis, intraoperative coagulation
Precautions for the use of plasma coblation wand in combination with plasma console:
(a) Check the expiration date and package integrity of the disposable coblation wand before use.
(b) The patient should not come into contact with the metal components of grounded equipment, and the use of antistatic plates is recommended.
(c) The disposable coblation wand cable should be kept away from patients and other leads, and temporarily unused probes should be stored away from patients.
(d) If the output is significantly reduced or the equipment fails to function normally, it may indicate poor probe contact or improper use.
(e) Flammable cleaning agents and solvents should be evaporated before using the plasma surgical system equipment, and flammable fluids should be wiped off from the patient's body and cavity.
(f) High-frequency current may interfere with cardiac pacemakers, so the current loop should not pass through the active implantable device.
(g) When installing the disposable coblation wand and powering on the equipment, avoid contact between the electrode and metal enclosure, and keep physiological monitoring equipment away from the probe as much as possible.